Rebates for social housing retrofit support program

horizontal-line-red

Please note final deadlines for the Social Housing Retrofit Support program:

  • Participants must have received a commitment letter from FortisBC by December 31, 2023 with approval for energy conservation measures such as gas furnaces, boilers, water heaters, condensing make up, air-handing and rooftop units.
  • Participants have 12 months from the commitment letter date to install eligible equipment and ensure it’s operational (December 31, 2024 the latest).
  • Participants have 90 days after the equipment is operational to submit their rebate application and all applicable documentation.

Through this program, we will continue to offer funding for energy studies, various energy conservation measures and implementation support.

horizontal-line-red

Gas rebates

TypeRebateRequirements
Gas absorption heat pumps75 per cent of the total project costs, up to $200,000

Visit the gas absorption heat pump rebates page for eligible models.

TypeRebateRequirements
Combination oven$2,000 - $3,000 per unit

For details about eligible gas models, see the eligible appliance list.

Conveyor ovens (more than 25 inches conveyor width)$2,500 per unit
Convection ovens$1,000 per unit
Rack oven$2,500 - $3,500 per unit
Fryer$1,000 per vat
Large vat fryer$1,200 per vat
Griddle$500 per unit
Steam cooker$200 per unit
Type Rebate Requirements
Solar hot water $27,000 per unit

For preheating water for domestic use. This measure may be considered when coupled with other energy conservation measures.

Piping insulation $4 per linear foot

For water and heating pipes.

TypeRebateRequirements
Heating plant controller $1,160 per unit

To reset boiler supply water based on outdoor air temperature.

Programmable thermostat $50 per unit

Must replace manual thermostat.

Vent damp for atmospheric boiler $2,140

To reduce standby losses of atmospheric boilers.

​Hydronic Additives*​$350 per gallon

​The building's primary heating system must be hydronic.*

The additives must be listed on our qualified product list.

*Only available to gas customers.

TypeRebateRequirements
Insulationroof$0.15 x R-value x square feet

Insulation rebates are independent of climate zone.

Continuous insulation, including deck roofs, is based on the cost of interior and exterior insulation and attachment.

walls$0.16 x R-value x square feet
WeatherstrippingTBD 
Windows$50 per unit/square feet

For metal and nonmetal as well as double or triple glazing.


Electricity rebates

Cooking appliances

TypeRebateRequirements
ENERGY STAR convection oven half$250 per unit

Commercial electric cooking appliances must meet all eligibility requirements for ENERGY STAR certification in their category.

full$300 per unit
ENERGY STAR fryerstandard size$200 per unit
large vat$850 per unit
ENERGY STAR griddle$550 per unit
ENERGY STAR hot food holding cabinetless than 368 L (13 cu. ft.)$150 per unit
368 to 793 L (13 to 28 cu. ft.)$600 per unit
greater than 793 L (28 cu. ft.)$1,600 per unit
ENERGY STAR steam cooker3 pan$1,750 per unit
4 pan$2,100 per unit
5 pan$2,450 per unit
6 pan$2,800 per unit

Dishwashers

TypeRebateRequirements
ENERGY STAR low-temperature single tank door dishwasher$400

Building hot water must be heated electrically

Dishwashers must be on the ENERGY STAR list of certified commercial dishwashers.

ENERGY STAR high-temperature single tank door dishwasher$700
ENERGY STAR high-temperature single tank conveyor dishwasher$1,200
ENERGY STAR high-temperature under counter dishwasher$1,600

Display cases

TypeRebateRequirements
Anti-sweat heater humidistat controllow temperature (must reduce anti-sweat heater run time by at least 50 per cent)$73 per linear foot

The device must control the anti-sweat heater load of reach-in doors, which includes any heating element in door rail, glass and frame.

medium temperature (must reduce anti-sweat heater run time by at least 80 per cent)

Heat controls must automatically modulate heater output based on environmental conditions, as measured by an integrated sensor.

Refrigerated display case with doors (medium temperature: 0 to 5 °C)$220 per linear foot

Display cases must replace a vertical model without doors and have a temperature of 0 to 5 °C.

Refrigerated display case night cover$30 per linear foot

Night covers should not be in use prior to rebate application.

When in use, covers must be applied for at least six hours in a 24-hour period.

You are encouraged to consider compressor capacity modulation when the night cover is applied and to consult the case manufacturer for recommendations on case operation with night covers.

Electronically commutated motor systems

TypeRebateRequirements
Electronically commutated motor systemslow temperature$75 per unit

All makes and models are eligible.

medium temperature$77.50 per unit

Entire motor replacement only.

Refrigerators

TypeRebateRequirements
ENERGY STAR glass door refrigeratorless than 425 L (15 cu. ft.)$220 per unit

Fridges must be vertical transparent door refrigerators on the ENERGY STAR list of certified commercial refrigerators and freezers.

425 to 850 L (15 to 30 cu. ft.)$285 per unit
850 to 1,416 L (30 to 50 cu. ft.)$350 per unit
greater than 1,416 L (50 cu. ft.)$400 per unit
ENERGY STAR solid door refrigeratorless than 425 L (15 cu. ft.)$250 per unit

Fridges must be vertical solid door refrigerators on the ENERGY STAR list of certified commercial refrigerators and freezers.

425 to 850 L (15 to 30 cu. ft.)$320 per unit
850 to 1,416 L (30 to 50 cu. ft.)$400 per unit
greater than 1,416 L (50 cu. ft.)$500 per unit

Split system air source heat pumps

Split systems include central systems, mini-split (ducted) and mini-split (ductless). 

Type
​Capacity
(tonnes)
Rebate
Certification requirementsPerformance requirements
Split ​​system

​less than 5.4
$2,000 per unit
  • ENERGY STAR or AHRI 210/240 certified
  • heating seasonal performance factor (HSPF) of 10 or higher
  • seasonal energy efficiency rating (SEER) of 16 or higher​
  • if the product is tested under new HSPF2/SEER2 Standard:
    • HSPF2 of 8.5 or higher
    • SEER2 of 15.2 or higher
​5.4 to 11
$450 per tonne
  • AHRI 340/360 certified
  • EER of 11 or higher
  • COP of 3.4 or higher
​more than 11
$500 per tonne
  • EER of 10.4 or higher
  • COP of 3.2 or higher ​

Rooftop unit air source heat pumps

Type
​Capacity
(tonnes)
Rebate
Certification requirementsPerformance requirements
Rooftop unit

​less than 5.4
$2,000 per unit
  • ENERGY STAR certified
  • EER of 12 or higher​​
​5.4 to less than 11
$450 per tonne
  • AHRI 340/360 certified
  • ​​EER of 12 or higher
  • integrated energy efficiency rating (IEER) of 12.4 or higher
  • COP of 3.4 or higher​
​11 to less than 15
$500 per tonne
​15 or more
$550 per tonne

Variable refrigerant flow (VRF) systems

TypeRebateRequirements
Standard VRF (two pipe)$600 per tonne
  • ​​​AHRI 1230 certified​​
Heat recovery VRF (two or three pipes)
$750 per tonne

Heat pump water heaters

TypeRebateRequirements
All-in-one heat pump$2,000 per unit
CO2 heat pump system$3,000 per unit

LED backlit signage

TypeRebateRequirements
LED signage$12 per unit

For retrofit projects only.

LED strips/modules/bars (where described application is signage) must be replacing fluorescent sign lighting.

Rebate available on LED signage to the lesser of equivalent lumen output OR up to two times the existing linear feet of T12HO OR up to one times the existing linear feet of neon.

Product must be CSA/UL certified, with a minimum five-year warranty and 50,000 L70 hours.

Must be suitable for damp locations (e.g. exterior application).

LED exterior and parking garage lighting

TypeRebateRequirements
LED flood light251 to 350 W$175 per unitFixtures must be listed and approved by DesignLights Consortium (DLC)® and be categorized as outdoor with the primary use of architectural flood and spot luminaires.
LED fuel canopy luminaireup to 100 W$80 per unitFixtures must be listed and approved by DesignLights Consortium (DLC) and be categorized as outdoor with the primary use of fuel canopy luminaires.
101 to 250 W$125 per unit
LED parking garage luminaireup to 70 W$70 per unitFixtures must be listed and approved by DesignLights Consortium (DLC) and be categorized as outdoor with the primary use of parking garage luminaires.
71 to 120 W$98 per unit
LED wall pack luminaire31 to 60 W$76 per unitFixtures must be llisted and approved by DesignLights Consortium (DLC)  and be categorized as outdoor with the applicable primary use of full-cutoff wall-mounted area luminaires.
61 to 120 W$100 per unit

LED interior luminaires

TypeRebateRequirements
LED ENERGY STAR fixtureup to 40 W$24 per unit LED fixtures must be listed and approved on the ENERGY STAR certified light fixtures list.
LED interior trofferup to 40 W$40 per unitFixtures must be listed and approved by the DesignLights Consortium (DLC), and categorized as indoor with the primary use of troffer.
41 to 80 W$56 per unit
LED high-bay luminaireup to 200 W$110 per unitFixtures must be listed and approved by the DesignLights Consortium (DLC), and categorized as indoor – high bay with the primary use of high bay luminaires for commercial and industrial buildings.
201 to 250 W$150 per unit
251 to 300 W$170 per unit
LED low-bay luminaire50 to 100 W$84 per unit

Fixtures must be listed and approved by the DesignLights Consortium (DLC), and categorized as indoor – high bay with the primary use of low bay luminaires for commercial and industrial buildings.

101 to 150 W$98 per unit

LED lamps

TypeRebateRequirements
LED BR style lamp10 to 18 W$7 per unitLamps must be listed and approved on the ENERGY STAR certified bulb list.
LED MR16 style lampup to 7 W$8 per unit
LED PAR style lampup to 12 W$10 per unit
13 to 24 W
LED T8 lamp, 4 ftup to 13 W$5 per unit

For retrofit projects only.

Lamps must be listed and approved by the DesignLights Consortium (DLC) and categorized as indoor - linear replacement lamps.

14 to 22 W
LED T5HO lamp, 4 ftup to 30 W$5 per unit

LED street lights and exterior luminaires

TypeRebateRequirements
LED area and roadway luminairesup to 60 W$60 per unitFixtures must be listed and approved by the DesignLights Consortium (DLC) and categorized as outdoor, with pole/arm-mounted area and roadway luminaires as the primary use.
61 to 90 W$83 per unit
91 to 120 W$100 per unit
121 to 200 W$120 per unit
201 to 300 W$185 per unit

Lighting controls and occupancy sensors

TypeRebateRequirements
Occupancy sensorceiling or wall-mounted$35 per unit

Occupancy sensors with a manual “on” switch override are not eligible.

Occupancy sensors must be commercial grade and have a principle of operation of passive infrared, ultra sonic or a combination only.

ceiling or wall-mounted

Photocell sensorceiling or wall-mounted$24 per unitPhotocell sensors must be integral to the fixture.
Type Rebate Requirements
Variable speed drive less than 20 hp $140 per motor hp

Only retrofit projects are eligible.

Variable speed drive must be retrofitted to an existing motor that has not been previously integrated with a variable speed drive.

Motor must be running a minimum of 2,000 hours per year.

Variable speed drive must control the motor's frequency in response to a variable load.

Variable speed drives used for soft start only are not eligible.

20 hp or greater $112 per motor hp